找到“electrophysiology*”的 19 条结果

  • DM660 Module (Dummy Membrane) - Physiologic Instruments
    DM660 Module (Dummy Membrane)
    The DM660 Module is a single channel dummy membrane to be used with the VCC600 single channel clamp.  The DM660 module is an electronic dummy membrane used to simulate an Ussing experiment. It is useful both in verifying the function of the VCC600 voltage/current clamp and also as a learning...
    常规价格
    $237.00
    常规价格
    促销价
    $237.00
  • EasyMount Ussing chamber system designed for rat intestinal and epithelial tissue studies, featuring multi-channel Ussing chambers, large-format tissue sliders, voltage clamp amplifier array, perfusion and stimulation modules, and real-time electrophysiology and ion transport data monitoring for advanced transepithelial transport, TEER measurement, and Ussing chamber research applications.
    EM8-R EasyMount Ussing Chamber System for Rat Tissue
    Designed for mounting intestinal tissues, specifically rat tissues for
    Ion Transport, barrier function, and epithelial electrophysiology research


    The P2250 EasyMount Ussing Chamber System is a specialized tool designed for efficiently mounting and studying rat intestinal tissues with precision and ease. Featuring a 5 x 22 mm oblong aperture for a consistent 1.0 cm² tissue area, it simplifies the tissue preparation process using P2252 sliders with curved pins for secure and accurate placement. With a versatile half-chamber volume range of 2.0-7.0 ml (optimal at 5 ml per half), it ensures adaptability to various experimental setups. Ordering additional P2252 sliders is recommended to streamline workflow. Ideal for researchers, the P2250 system delivers reliability and convenience for advanced tissue studies.

    常规价格
    $0.00
    常规价格
    促销价
    $0.00
  • Two Syringes With Filling Needles - Physiologic Instruments
    FN15-2 Two Syringes With Filling Needles
    Two syringes with ball shape metal-tipped 15 gauge needles (Model: FNS15-2) for filling and emptying EasyMount chambers.
    常规价格
    $20.00
    常规价格
    促销价
    $20.00
  • EasyMount low-volume Ussing chamber system featuring multi-channel chambers, tissue sliders, voltage clamp amplifier, perfusion modules, and data-acquisition monitor for advanced epithelial transport and electrophysiology research.
    EM8-LV EasyMount Low Volume Ussing Chamber System
    Designed for a variety of small tissues sizes in our low volume chambers for
    Drug Solutions & FLUX Measurements


    The P2400 EasyMount Low Volume System is designed for the study of transport in tissues where low net transport quantities or assays requiring higher solute concentrations are involved. This system accommodates various tissue sizes and operates within a low-volume chamber environment.

    The system includes the EasyMount base unit, P2400 low-volume chambers (with working volumes ranging from 1.0 mL to 5.0 mL per chamber half), and a selection of tissue sample holders (one per chamber). A range of holders is available, supporting small tissue samples such as human intestinal or nasal mucosal biopsies, mouse pup intestine, cornea, and larger tissues up to 0.71 cm² (9.5 mm diameter). Custom holders can be fabricated to suit specific tissue requirements. Note that P2400 series sliders are sold separately from the system.

    常规价格
    $0.00
    常规价格
    促销价
    $0.00
  • 6-Channel Voltage Current Clamp Model VCC MC6 by Physiologic Instruments for studying epithelial transport and barrier function in physiological and pharmaceutical research.
    6-Channel Voltage Current Clamp with OptiGain
    Precision voltage–current control for epithelial ion transport and CFTR studies.
    常规价格
    $0.00
    常规价格
    促销价
    $0.00
  • The VCC-MC8 is a Multi-Channel Voltage Current Clamp with OptiGain is a multi-channel voltage/current clamp designed to be a flexible tool for studying ion transport mechanisms by in vitro epithelial tissues. The voltage current clamp is used with our EasyMount Ussing Chamber System.
    8-Channel Multi-Channel Voltage Current Clamp with OptiGain
    Designed for CFTR function assays, ion channel research, & transepithelial current measurements.
    常规价格
    $0.00
    常规价格
    促销价
    $0.00
  • P2304S EasyMount Ussing Chamber Slider for Small Tissue with Silver Electrodes, made by Physiologic Instruments
    P2304S EasyMount Ussing Chamber Slider
    APETURE SIZE: 2.7x11.2MM | Membrane Area = 0.3 cm² | With Silver Electrodes
    Designed for small tissue specimens such as mouse intestine

    The P2304S Ussing Chamber Slider is specifically engineered for advanced physiological studies involving elongated tissue specimens, such as mouse intestine sections. Featuring a 2.7 x 11.2 mm aperture with an exposure area of 0.3 cm², this slider offers a precise platform for examining transport and barrier functions in extended tissues, ensuring reliable and reproducible data across experiments.

    This special chamber slider is equipped with integrated silver electrodes to enable controlled transmural electric field stimulation, supporting studies that require precise electrical modulation across tissue layers. Compatible with the EasyMount Chamber Model P2300, the P2304S slider provides a robust solution for researchers conducting complex studies on small, elongated tissue samples, enhancing both experimental control and data fidelity.


    ⦿ To be used with P2300 EasyMount Ussing Chambers

    常规价格
    $332.00
    常规价格
    促销价
    $332.00
  • Optimize your transport and electrophysiological studies with the P2302N EasyMount Ussing Chamber Slider. Featuring an advanced Nunc/Anapore polycarbonate culture insert with an 8 mm tissue-culture-treated membrane supported by a removable ring, this device ensures stable, adaptable positioning in EasyMount ussing chambers.
    P2302N EasyMount Ussing Chamber Slider
    APETURE SIZE: 8.0MM | Area = 0.5 cm². Dia = 10mm
    Designed for Nunc/Anapore Culture Inserts

    Optimize your transport and electrophysiological studies with the P2302N EasyMount Ussing Chamber Slider. Featuring an advanced Nunc/Anapore polycarbonate culture insert with an 8 mm tissue-culture-treated membrane supported by a removable ring, this device ensures stable, adaptable positioning in EasyMount ussing chambers. The P2302N EasyMount Slider is an essential tool for enhancing research efficiency and precision.


    ⦿ To be used with P2300 EasyMount Ussing Chambers

    常规价格
    $230.00
    常规价格
    促销价
    $230.00
  • EasyMount Ussing chamber system for cell culture and animal tissue electrophysiology, featuring multi-channel Ussing chambers, epithelial tissue sliders, voltage clamp amplifier array, perfusion and stimulation modules, and real-time transepithelial transport data displayed on the monitoring software for advanced Ussing chamber TEER and ion transport research.
    EM8-C EasyMount Ussing Chamber System for Cell & Tissue
    Designed for a variety of cell culture inserts & tissues in
    Ion Transport, barrier function, and epithelial electrophysiology research


    The P2300 EasyMount Ussing System for Cell & Tissue is an advanced platform for studying ion transport, barrier function, and epithelial electrophysiology in a controlled environment. Utilizing the flexible P23xx series sliders, the system supports a range of tissue types, from cell culture inserts to specific animal and human samples. Systems available in optional: CE

    常规价格
    $0.00
    常规价格
    促销价
    $0.00
  • The EasyMount Ussing chamber together with the P2302 Ussing chamber slider and Snapwell cell culture insert have enabled many scientific advances particularly towards understanding genetic transport defects in cystic fibrosis.
    P2302 EasyMount Ussing Chamber Slider
    Apeture size = 12mm | Area = 1.12 cm² Dia = 12mm
    Designed for Snapwell Cell Culture Inserts | P2302 (Inserts Not included with Slider)

    The Corning Transwell Snapwell has become a mainstay for growing epithelial cells. Its large area (1.12 cm2) and shallow depth are ideal for transport and electrophysiological research in the EasyMount Ussing chamber. The P2302 EasyMount Slider is designed to securely hold these inserts without stress on the membrane and to position the membrane perfectly between the two halves of the P2300 Ussing chamber.

    The mounting procedures for placing the Snapwell into the P2302 slider and then into the chamber are both easy and fast. The Snapwell is removed from the culture dish, separated from its holder, drained of media, and placed with its basal side against the red O-ring in the P2302 slider. Wipe the end and sides of the slider to remove any saline and “slide” the Snapwell+P2302 in the slot between the two chamber halves until it reaches the hard stop. Turn the thumbscrew on the chamber to gently squeeze the chamber halves together. Only light pressure between the chamber halves and the slider is required to make a watertight seal. Excessive pressure can distort the culture membrane and alter the electrical parameters. The procedure for mounting the tissue takes less than 30 seconds to accomplish. This system is ideal for transport and electrophysiological measurements. The P2302 enables effortless transfer of confluent cell layers directly into EasyMount Ussing Chambers, providing researchers with a streamlined, effective solution for high-quality results.


    ⦿ To be used with P2300 EasyMount Ussing Chambers

    常规价格
    $223.00
    常规价格
    促销价
    $223.00