EasyMount Ussing Chamber P2250The P2250 Intestinal EasyMount Ussing Chamber is specifically designed for studies using intestinal tissues, such as rat, guinea pig and rabbit. The chamber uses a custom designed EasyMount Ussing Chamber Slider (P2252) for mounting intestinal tissues, which has an oblong aperture of 5 x 22 mm and an area of...
- Regular price
- $637.00
- Regular price
-
- Sale price
- $637.00
- Unit price
- per
-
EasyMount Ussing Chamber P2300The P2300 Standard EasyMount Ussing Chamber is designed for studies using a variety of animal tissues and/or cell cultures. The chamber uses custom designed EasyMount Ussing Chamber Sliders (See the complete list of P2300 Series sliders) for mounting tissues or permeable membrane supports (Snapwell, Transwell, Millicell, Nunc). Usable half chamber...
- Regular price
- $604.00
- Regular price
-
- Sale price
- $604.00
- Unit price
- per
-
EasyMount Ussing Chamber P2400The P2400 Low-Volume EasyMount Ussing Chamber is designed for studies using a variety of animal tissues. The chamber uses custom designed EasyMount Ussing Chamber Sliders (Click HERE to see a complete list of P2400 Series sliders) for mounting tissues. The low-volume chamber may be preferred when using highly expensive drug...
- Regular price
- $659.00
- Regular price
-
- Sale price
- $659.00
- Unit price
- per
-
P2252 EasyMount Slider with 5 x 22mm Aperture for Mounting Large Intestinal TissueThe P2252 EasyMount Slider has an oblong 4.8 x 22 mm aperture and is designed for mounting intestinal tissues with a surface area of no less than 1 cm2 and for use with EasyMount P2250 Chambers. The P2252 EasyMount Slider is composed of a top clear and bottom white segment....
- Regular price
- $208.00
- Regular price
-
- Sale price
- $208.00
- Unit price
- per
-
Multipurpose EasyMount Ussing Chamber Stand SystemsThese exceptional Multipurpose EasyMount Ussing Chamber Stand Systems includes individual Ussing Diffusion Chambers, a heating block for temperature control, needle valves for adjustment of gas flow used for oxygenation and gas lift stirring, Ag/AgCl reference electrodes for measuring transepithelial voltage and passing current and leads for connecting the electrodes to...
- Regular price
- From $3,358.00
- Regular price
-
- Sale price
- From $3,358.00
- Unit price
- per
-
Low-Volume EasyMount Ussing Chamber Stand SystemsThese exceptional Low Volume EasyMount Ussing Chamber Stand Systems include individual Ussing Chambers, a heating block for temperature control, needle valves for adjustment of gas flow used for oxygenation and gas lift stirring, Ag/AgCl reference electrodes for measuring transepithelial voltage and passing current and leads for connecting the electrodes to...
- Regular price
- From $3,550.00
- Regular price
-
- Sale price
- From $3,550.00
- Unit price
- per
-
Rat Tissue EasyMount Ussing Chamber Stand SystemsThese exceptional Rat Tissue EasyMount Ussing Chamber Stand Systems include individual Ussing P2250 chambers specifically designed for mounting intestinal tissues, a heating block for temperature control, needle valves for adjustment of gas flow used for oxygenation and gas lift stirring, Ag/AgCl reference electrodes for measuring transepithelial voltage and passing current...
- Regular price
- From $3,567.00
- Regular price
-
- Sale price
- From $3,567.00
- Unit price
- per
Chamber Components
The EasyMount stand is made of brightly anodized aluminum and uses spring-loaded brackets ("cradles") to hold the chamber firmly against a plate of aluminum we call a "heatblock". Water from a circulating water bath is pumped though the heatblock to control the temperature in the chambers. Air control valves located atop the heatblock are used to finely adjust the flow of gas through the chamber to provide circulation and stirring as well as oxygenation of the solutions bathing the tissues.
The EasyMount Ussing Chamber System has been designed for ease of use and easy cleanup while working with up to 2, 4, 6 or 8 tissue or cell culture samples simultaneously. Tissues and/or cell cultures are first placed in a holder we call a "slider" which is then inserted into the chamber. Unlike competing Ussing systems, the chamber does not have to be removed from its holder on the stand nor do the electrodes have to be disturbed during the process of mounting the tissue sample.
Moreover, because the tissues are first mounted on a slider, a wide variety of epithelial tissues can be studied in the same chamber simply by selecting a slider appropriate for that tissue. Only the slider needs to be changed, not the whole chamber.
EasyMount Ussing Chamber Systems accommodate three types of EasyMount Ussing Chambers:
Intestinal Specific P2250 Chambers (EM-RSYS Series) Accommodates intestinal tissues and has a usable half chamber volume of 2.0 - 7.0 ml
Standard P2300 Chambers (EM-CSYS Series) Accommodates the largest variety of tissues and cell cultures and has a usable half chamber volume of 2.0 - 7.0 ml
Low-Volume P2400 Chambers (EM-LVSYS Series) Accommodates a large variety of tissues and has a usable half chamber volume of 1.0 - 7.0 ml