-
P2302T₁₂ EasyMount Ussing Chamber SliderAPETURE SIZE: 12MM | Area = 1.12 cm²Designed for Corning-Costar Transwell Inserts
The P2302T₁₂ EasyMount Ussing Chamber Slider offers an efficient, precision-engineered solution for integrating 12 mm Corning-Costar Transwell Inserts with an aperture area of 1.12 cm². Designed to meet the demands of high-sensitivity assays, such as advanced drug transport, permeability, and cellular barrier studies, this slider provides a stable, secure fit for Transwell Inserts, enabling straightforward assembly and optimal positioning in our EasyMount Ussing chambers.
Its versatility supports both vertical and horizontal experimental setups, making it an invaluable tool for labs conducting rigorous cell culture experiments. The P2302T₁₂ EasyMount Slider streamlines complex workflows, providing reproducible, reliable data, and enhancing experimental accuracy for scientists focused on cellular function and transport research.
⦿ To be used with P2300 EasyMount Ussing Chambers- Regular price
- $242.00
- Regular price
-
- Sale price
- $242.00
- Unit price
- / per
-
P2302N EasyMount Ussing Chamber SliderAPETURE SIZE: 8.0MM | Area = 0.5 cm². Dia = 10mmDesigned for Nunc/Anapore Culture Inserts
Optimize your transport and electrophysiological studies with the P2302N EasyMount Ussing Chamber Slider. Featuring an advanced Nunc/Anapore polycarbonate culture insert with an 8 mm tissue-culture-treated membrane supported by a removable ring, this device ensures stable, adaptable positioning in EasyMount ussing chambers. The P2302N EasyMount Slider is an essential tool for enhancing research efficiency and precision.
⦿ To be used with P2300 EasyMount Ussing Chambers- Regular price
- $218.00
- Regular price
-
- Sale price
- $218.00
- Unit price
- / per
-
P2302M EasyMount Ussing Chamber SliderAPETURE SIZE: 8.75MM | Membrane Area = 0.60 cm² Designed for Millipore Millicell Culture Inserts
Achieve accurate electrophysiological studies with the P2302M EasyMount Ussing Chamber Slider, featuring a aperture of 8.75mm perfect for millicell cell culture inserts.
Our P2302M EasyMount Ussing Chamber Slider is the right setup when using Millicell® cell culture inserts in an ussing chamber. With this slider you can simulate the three-dimensional environment for natural, multidimensional cell growth. Access both surfaces of cell layers for more relevant in vitro models and accurate results. Perfect for toxicity screening, primary and secondary screening, and cell signaling studies.
⦿ To be used with P2300 EasyMount Ussing Chambers- Regular price
- $218.00
- Regular price
-
- Sale price
- $218.00
- Unit price
- / per
-
GWB1 Gas Washing Bottle (1 L)GWB1 Gas Washing Bottle (1 L) Our GWB1 washing bottle has been designed for purifying or saturating gases by passing them through a liquid. Made of glass, the gas washing bottle consists of an inlet tube that directs the gas into the liquid, allowing it to bubble through and interact...
- Regular price
- $304.00
- Regular price
-
- Sale price
- $304.00
- Unit price
- / per
-
FN15-2 Two Syringes With Filling NeedlesTwo syringes with ball shape metal-tipped 15 gauge needles (Model: FNS15-2) for filling and emptying EasyMount chambers.
- Regular price
- $19.00
- Regular price
-
- Sale price
- $19.00
- Unit price
- / per
-
TK-7 Tubing and setup kitTK-7 Tubing Kit for Water Bath. Includes tubes and connections to setup the water bath to the chamber stand.
- Regular price
- $102.00
- Regular price
-
- Sale price
- $102.00
- Unit price
- / per
-
EM-8R EasyMount Ussing Chamber System for Rat TissueDesigned for mounting intestinal tissues, specifically rat tissues for Ion Transport, barrier function, and epithelial electrophysiology research
The P2250 EasyMount Ussing Chamber System is a specialized tool designed for efficiently mounting and studying rat intestinal tissues with precision and ease. Featuring a 5 x 22 mm oblong aperture for a consistent 1.0 cm² tissue area, it simplifies the tissue preparation process using P2252 sliders with curved pins for secure and accurate placement. With a versatile half-chamber volume range of 2.0-7.0 ml (optimal at 5 ml per half), it ensures adaptability to various experimental setups. Ordering additional P2252 sliders is recommended to streamline workflow. Ideal for researchers, the P2250 system delivers reliability and convenience for advanced tissue studies.
- Regular price
- $0.00
- Regular price
-
- Sale price
- $0.00
- Unit price
- / per
-
Rat Tissue EasyMount Ussing Chamber Stand SystemsThese exceptional Rat Tissue EasyMount Ussing Chamber Stand Systems include individual Ussing P2250 chambers specifically designed for mounting intestinal tissues, a heating block for temperature control, needle valves for adjustment of gas flow used for oxygenation and gas lift stirring, Ag/AgCl reference electrodes for measuring transepithelial voltage and passing current...
- Regular price
- From $3,567.00
- Regular price
-
- Sale price
- From $3,567.00
- Unit price
- / per
-
P2252 EasyMount SliderAPETURE SIZE: 4.775x22.02 MM | Area = 1.0 cm²Designed for Rat Intestional Tissues
The P2252 EasyMount Slider has an oblong 4.8 x 22 mm aperture and is designed for mounting intestinal tissues with a surface area of no less than 1 cm² and for use with EasyMount P2250 Chambers. Composed of a top clear and bottom white segment. Tissues are mounted by pressing the tissue over short, curved pins lining a matching aperture on the slider.
The aperture has a surrounding recess to minimize edge-effect caused by minimal compression from mounting. The large surface area is useful when performing ion flux or drug permeability studies. The large surface area also maximizes detecting endogenous peptide secretion from the lumen or from the basolateral side.
⦿ To be used with EasyMount P2250 Chamber- Regular price
- $208.00
- Regular price
-
- Sale price
- $208.00
- Unit price
- / per
-
Multipurpose EasyMount Ussing Chamber Stand SystemsThese exceptional Multipurpose EasyMount Ussing Chamber Stand Systems includes individual Ussing Diffusion Chambers, a heating block for temperature control, needle valves for adjustment of gas flow used for oxygenation and gas lift stirring, Ag/AgCl reference electrodes for measuring transepithelial voltage and passing current and leads for connecting the electrodes to...
- Regular price
- From $3,358.00
- Regular price
-
- Sale price
- From $3,358.00
- Unit price
- / per
-
Low-Volume EasyMount Ussing Chamber Stand SystemsThese exceptional Low Volume EasyMount Ussing Chamber Stand Systems include individual Ussing Chambers, a heating block for temperature control, needle valves for adjustment of gas flow used for oxygenation and gas lift stirring, Ag/AgCl reference electrodes for measuring transepithelial voltage and passing current and leads for connecting the electrodes to...
- Regular price
- From $7,161.00
- Regular price
-
- Sale price
- From $7,161.00
- Unit price
- / per
-
EM8-LV EasyMount Low Volume Ussing Chamber System for Cell & TissueDesigned for a variety of small tissues sizes in our low volume chambers for Drug Solutions & FLUX Measurements
The P2400 EasyMount Low Volume System is designed for the study of transport in tissues where low net transport quantities or assays requiring higher solute concentrations are involved. This system accommodates various tissue sizes and operates within a low-volume chamber environment.
The system includes the EasyMount base unit, P2400 low-volume chambers (with working volumes ranging from 1.0 mL to 5.0 mL per chamber half), and a selection of tissue sample holders (one per chamber). A range of holders is available, supporting small tissue samples such as human intestinal or nasal mucosal biopsies, mouse pup intestine, cornea, and larger tissues up to 0.71 cm² (9.5 mm diameter). Custom holders can be fabricated to suit specific tissue requirements. Note that P2400 series sliders are sold separately from the system.
- Regular price
- $0.00
- Regular price
-
- Sale price
- $0.00
- Unit price
- / per
-
EM8-C EasyMount Ussing Chamber System for Cell & TissueDesigned for a variety of cell culture inserts & tissues in Ion Transport, barrier function, and epithelial electrophysiology research
The P2300 EasyMount Ussing System for Cell & Tissue is an advanced platform for studying ion transport, barrier function, and epithelial electrophysiology in a controlled environment. Utilizing the flexible P23xx series sliders, the system supports a range of tissue types, from cell culture inserts to specific animal and human samples. Systems available in optional: CE
- Regular price
- $0.00
- Regular price
-
- Sale price
- $0.00
- Unit price
- / per
-
P2060 Dual Air Control ValveThe Dual Air Control Valve (Model: P2060) easily controls the amount of gas bubbling your chambers with fingertip control of the screw type precision air valves. Includes two needle valves in an aluminum housing. Mounts on all EasyMount chamber stands.
- Regular price
- $98.00
- Regular price
-
- Sale price
- $98.00
- Unit price
- / per
-
DM660 Module (Dummy Membrane)The DM660 Module is a single channel dummy membrane to be used with the VCC600 single channel clamp. The DM660 module is an electronic dummy membrane used to simulate an Ussing experiment. It is useful both in verifying the function of the VCC600 voltage/current clamp and also as a learning...
- Regular price
- $237.00
- Regular price
-
- Sale price
- $237.00
- Unit price
- / per
-
DM MC6 Module (Dummy Membrane)The DM_MC6 Module is an input module for connecting the voltage and current electrodes to the VCC MC2, VCC MC6, VCC MC8 and all expandable instruments. The DM MC6 is a small, shielded unit that should be mounted close to individual Ussing chambers and is recommended for use with both our EasyMount...
- Regular price
- $218.00
- Regular price
-
- Sale price
- $218.00
- Unit price
- / per
-
Data Acquisition System Hardware for A&A U100U100 Data Acquisition System Hardware for A&A
- Regular price
- $0.00
- Regular price
-
- Sale price
- $0.00
- Unit price
- / per
-
Circulating Temperature Control Water BathCirculating Temperature Control The PS-MX-120 heating bath circulator offers quick heat up times, a small footprint to conserve valuable bench space. All models feature: Powerful force and suction pumps to circulate long distances or to open or closed containers Seamless stainless steel tanks for excellent fluid compatibility and easy cleaning...
- Regular price
- $0.00
- Regular price
-
- Sale price
- $0.00
- Unit price
- / per
-
P2300-Cap Chamber CapsCaps for P2300, P2400, and P2250 Chambers
- Regular price
- $126.00
- Regular price
-
- Sale price
- $126.00
- Unit price
- / per
-
Acquire & Analyze 3 — Multi-Channel Data Acquisition & Integrated pH ControlDesigned for Transepithelial Electrophysiology Data AcquisitionACQUIRE & ANALYZE is a specialized data acquisition and analysis system for measuring bioelectrical properties in epithelial tissues or cell layers on permeable membranes, used with VCC MC2, MC6, or MC8 voltage/current clamps. Designed specifically for transepithelial electrophysiology, it records and plots voltage, current, and transepithelial resistance (TEER) in real time from up to eight tissues, eliminating the need for post-processing to calculate TEER. The Windows®-based software provides an intuitive interface, allowing users to set parameters, select data collection rates, and generate compact files with minimal effort. By combining hardware, cables, and optimized software, it simplifies and enhances electrophysiological measurements for targeted research applications.
- Regular price
- $0.00
- Regular price
-
- Sale price
- $0.00
- Unit price
- / per


























